principal of cleaning centrifuge
The centrifuge separates solids from liquids
with centrifugal forces. The contaminated liquid is cared centrally into the
bowl through the rotor cover and thus falls onto the bottom of the solids insert
inside the bowl.
By centrifugal forces the liquid is spinning
off Centre outwards and rises towards the top of the inner wall of the bowl. The
cleaned liquid is removed into a tank. On their way to the top the heavy solids
are forced to the periphery and settle on the wall of the bowl
insert.
While the drum is standing still, the
residual liquid is drained into a tank, so that the separated solids have a very
low residual moisture.
When the insert is full, it easy can be removed and replaced by an empty one.
The centrifuge is ready for use again.
The changing of the solid insert takes approx. 2-3 minutes.